
AVANSA 25/6/180 circulation pump
- Head6 m
- Max. flow55 l/min
- Power input (3 speeds)93/67/46 W
- Installation length180 mm
- Connection6/4"
Circulation pumps, room and boiler thermostats, pure sine wave UPS units and gas detectors – everything for a dependable boiler room from a single brand, in stock in Žilina and backed by technical support over the phone.
updateUpdated: verifiedTechnically reviewed by the ATRIA SK s.r.o. technicians
AVANSA® is a brand of heating and safety equipment distributed across Europe by ATRIA Slovensko s.r.o., based in Žilina, Slovakia. The range covers what almost every family-home boiler room needs: circulation pumps for central heating, room and boiler thermostats, backup power supplies (UPS) for solid-fuel boilers, and gas and carbon monoxide detectors.
AVANSA circulation pumps have a cast-iron body and an asynchronous motor with three speeds, selected directly on the terminal box. They handle media from -10 to +110 °C at working pressures of up to 10 bar. The room thermostats are suitable for controlling most boilers with a switching voltage of 24 – 230 V and come in both wired and wireless versions. During a power cut, the backup power supplies deliver a pure sine wave output, so the circulation pump keeps running and the boiler can cool down safely. Gas detectors with a sensitivity of 10% of the lower explosive limit (LEL) can shut off the gas supply automatically when supplied as a set with a solenoid valve.
On this website you will find an overview of the full range, technical specifications, comparisons and practical advice on selection and wiring. All products are available from the ATRIASHOP.EU online store – most of them shipped straight from our warehouse in Žilina. Installers, heating contractors and resellers can buy on wholesale terms via atria-europe.com. If you are planning a complete heating system, take a look at our specialist website on H.P.W.® brass manifolds as well.
Five areas that together make up a complete and safe boiler room. Choose the one you are dealing with right now.

Three-speed pumps with 4, 6 and 8 m head, 130 or 180 mm installation length, plus a circulation pump for domestic hot water.
Viewarrow_forward
Room thermostats 2003 and 2007 (including wireless TX versions), AVANSA 110 pump controllers, clamp-on and immersion thermostats.
Viewarrow_forward
300 – 1050 W pure sine wave units for the circulation pumps of solid-fuel boilers, sold on their own or as a set with a battery.
Viewarrow_forward
Natural gas and LPG detectors, sets with G1/2", G3/4" and G1" solenoid valves, and a carbon monoxide detector.
Viewarrow_forward
How to choose a pump, size a backup power supply, position a detector and protect the boiler with an Aras magnetic filter.
Viewarrow_forwardA selection from across the whole range – from the pump to controls, backup power and detectors. Prices and availability are taken directly from the ATRIASHOP.EU online store.








Official distribution of the brand means goods in stock, expert advice and a clear point of contact whenever you need it.
We keep pumps, thermostats, detectors and backup power supplies in stock at our warehouse in Žilina, Slovakia. Current availability is shown next to every product.
Pump, backup power supply, controls and detector all work together – there is no need to piece together your boiler room equipment from several suppliers.
We are happy to help you choose a pump, size a backup power supply or wire up a thermostat – just call +421 917 133 664.
UPS sets with batteries, the Aras magnetic filter, the TH6 thermostatic radiator set, clamp-on thermostats and the STS safety valve – all in one place.
Order from an online store with clear prices including VAT and delivery to your door. Installers and resellers can buy on wholesale terms via atria-europe.com. Orders are also accepted by phone on +421 917 133 662.
ATRIA Slovensko s.r.o. is the official distributor of the AVANSA brand for Europe. We have a dedicated claims line: +421 917 710 567.
Most people are not looking for a brand but for a solution to a specific problem. Here is a shortcut to the right product.
Measure the installation length of the old pump (130 or 180 mm) and check the thread on the pump body (1", 6/4" or 2"). For a typical family home, an AVANSA circulation pump with a 6 m head is then usually enough, or the economical 4 m version for smaller systems. If you used to have an Aquart pump, we now sell the same models under the AVANSA brand with the same size designations.
If the water heater is far from the bathroom or kitchen, the AVANSA CP 15-1.5 recirculation pump will help. It keeps domestic hot water circulating between the cylinder and the taps, so hot water arrives almost immediately and does not run needlessly down the drain. It has a brass body suitable for drinking water, a power input of 25 W, a G 1/2" connection and a cable with a plug. Add a timer switch so that it runs only when you actually use hot water – for example in the morning and evening.
A solid-fuel boiler needs water to keep circulating even during a power cut. The basis is an AVANSA boiler backup power supply with a lead-acid battery, together with an AVANSA 110 C or 110 E pump controller, which switches the pump according to the boiler temperature, and an STS safety valve for the cooling loop. A carbon monoxide detector also belongs in the boiler room.
The biggest saving comes from an AVANSA room thermostat with a weekly programme – the boiler does not fire when nobody is at home and holds a lower temperature at night. If you do not want to run a cable, choose the wireless 2007 TX model. On the pump, set the lowest speed at which all the radiators still heat up.
A kitchen or boiler room should have an AVANSA gas detector – near the ceiling for natural gas, near the floor for LPG. In a kit with a solenoid valve, it shuts off the gas supply by itself in the event of a leak. The 150MC detector protects against carbon monoxide from a boiler or stove.
The AVANSA pump and thermostat are only part of the system. You will find manifolds with flow meters on the H.P.W.® brass manifolds website, and a heating installer or our technical support can help you size the number of circuits and the amount of pipe.
Six steps, from the pump to protecting the boiler against dirt. Each step links to a page with a detailed selection guide.
The key factors are head, flow rate, installation length (130 or 180 mm) and connection thread (1", 6/4" or 2"). A head of up to 6 m is usually sufficient for a typical family home, while larger and multi-zone systems need 8 m. Pump speed is set with a three-position switch. You will find an overview of the models on the Circulation pumps page.
During a power cut, the UPS immediately powers the pump from the battery so that the boiler can cool down safely. Allow a margin for the pump's start-up current – a 500 W unit is suitable for loads of up to approx. 250 W in total. Help with choosing the model and battery is on the Backup power supplies page.
The AVANSA 110 C or 110 E controller switches the pump on only once the boiler exceeds the set temperature and switches it off again after it has cooled down – depending on how the boiler is used, this can save up to 60% of the electricity and extend the pump's service life. The 110 Z model adds DHW cylinder heating, the 110 R controls two pumps and the 110 S a solar circuit. More on the Thermostats page.
The manual AVANSA 2003 maintains a single set temperature, while the programmable AVANSA 2007 allows up to 6 temperature changes a day according to a weekly programme. The TX versions work wirelessly with a receiver next to the boiler (range approx. 50 m) – particularly handy when renovating older buildings. See the comparison on the Thermostats page.
A gas boiler should always be paired with the AVANSA 100M gas detector – supplied as a set with a solenoid valve, it shuts off the gas supply by itself if a leak occurs. Carbon monoxide, which a gas detector cannot pick up, calls for the separate AVANSA 150MC detector. More on the Detectors page.
The Aras 3/4" magnetic filter captures ferrous debris with a neodymium magnet, while its filter mesh also traps non-magnetic particles from radiators and pipework. The pack includes a swivel boiler connection, a G3/4" ball valve and a spanner, and the magnet is easy to remove for cleaning. Maintenance tips are in the Advice section.
What each product line is designed for and where to find more details.
| Product line | Models | Typical use | More |
|---|---|---|---|
| Circulation pumps | 15/6/130, 25/4/130, 25/4/180, 25/6/130, 25/6/180, 25/8/180, 32/6/180, 32/8/180 | Heating circuits in family homes, boiler rooms, domestic water systems | Pumps |
| DHW circulation pump | CP 15-1.5 | Circulating domestic hot water between the cylinder and the taps | Pumps |
| Room thermostats | TH1, 2003, 2003 TX, 2007, 2007 TX | Room temperature control and boiler switching | Thermostats |
| Pump and boiler room thermostats | 110 C, 110 E, 110 R, 110 Z, 110 S | Switching pumps by the temperature of the boiler, DHW cylinder or solar collector | Thermostats |
| Clamp-on and immersion thermostats | TH 2A, TH-2B | Boiler pump overrun, underfloor heating safety cut-out, buffer tanks and cylinders | Thermostats |
| Thermostatic radiator set | TH6 (DN15 valve + head) | Temperature control of individual radiators | Thermostats |
| UPS backup power supplies | 300 W, 500 W, 700 W, 1050 W | Powering the circulation pumps of solid-fuel boilers during a power cut (battery sold separately) | Backup power |
| UPS + battery sets | 300 W + 45 Ah, AVANSA SET (500 W + 46 Ah), AVANSA SET I. (700 W + 55 Ah), 1050 W + 2 batteries | A ready-made backup solution without having to hunt for a suitable battery | Backup power |
| Gas detectors | 100M, 200M, sets with G1/2", G3/4", G1" solenoid valves | Natural gas (methane) and LPG, automatic shut-off of the gas supply | Detectors |
| Carbon monoxide detector | 150MC | Early warning of carbon monoxide (CO) poisoning | Detectors |
| Magnetic filter | Aras 3/4" | Capturing ferrous and non-magnetic debris from heating water | Advice |
Current prices in your currency and availability are always shown on the product cards on this website and directly in the ATRIASHOP.EU online store.
The most important manufacturer data in one place. Detailed tables for all models can be found on the pages of the individual product lines.
| Product | Power supply | Main performance figure | Operating conditions | Connection, size |
|---|---|---|---|---|
| AVANSA 25/6/180 circulation pump | 230 V, 46 / 67 / 93 W | head 6 m, max. 55 l/min | -10 to +110 °C, max. 10 bar, IP44 | 6/4" (DN25), length 180 mm |
| CP 15-1.5 recirculation pump | 220 V, 25 W | head 1.7 m, max. 6.8 l/min | 5 – 95 °C, max. 10 bar | G 1/2" (DN15), length 85 mm |
| AVANSA 2007 room thermostat | 2× 1.5 V AA | 6 times and temperatures per day, 7 – 35 °C | accuracy ±0.5 °C, IP30 | contact 24 V AC/DC – 250 V AC, 8 A |
| 2007 TX wireless thermostat | thermostat 2× AA, receiver 230 V | range approx. 50 m | 7 – 35 °C in 0.5 °C steps | receiver 24 V AC/DC – 250 V AC, 6 A |
| AVANSA 110 E pump controller | 230 V, 50 Hz | switches the pump at 5 – 80 °C | ambient -10 to +50 °C | switching current 6 A, 1.2 m sensor |
| AVANSA 500 W backup power supply | input 150 – 270 V AC | 800 VA, loads up to approx. 250 W | switchover < 4 ms, pure sine wave | 12 V battery up to 120 Ah |
| AVANSA 100M gas detector | AC 220 V, < 1.5 W | 10 % LEL, response < 30 s | -15 to +50 °C, alarm > 90 dB | output for 12 V DC valve |
| AVANSA 150MC CO detector | AC 220 V, < 3 W | 150 ± 80 ppm CO | -10 to +55 °C, alarm > 85 dB | – |
| Aras 3/4" magnetic filter | – | neodymium magnet + filter mesh | – | G3/4", swivel connection to the boiler |
A dash means that the figure is not stated for that product or does not apply. You will find the current price and availability with the products above.
A gas boiler simply switches off during a power cut. A boiler burning wood, coal or coke, however, cannot be stopped like that – the fuel in the firebox keeps burning until it has burnt out. If the circulation pump stops, heat is no longer carried away to the radiators, the water in the boiler overheats and the central heating system is at risk of boiling. The result can be a damaged boiler, leaks or a dangerous condition of the whole system.
The AVANSA backup power supply (UPS) is designed for exactly this situation. When the mains supply fails or the voltage falls outside the normal range, it switches to battery automatically in less than 4 ms, keeps the circulation pumps running and lets the boiler cool down safely. The switch-over is indicated on the display and by an audible signal. The output voltage is a pure sine wave, identical to the mains voltage in your home, which suits the motors of circulation pumps. Once the mains supply returns, the unit recharges the battery.
A circulation pump is an inductive load and may need up to twice its rated power when starting. That is why it is recommended to load the backup power supply to no more than 50% of its maximum output:
Add up the power input of all the pumps the unit is to back up, plus the boiler electronics if applicable. With three-speed AVANSA pumps this is a matter of tens of watts – the 25/6/180 model, for example, draws 93/67/46 W depending on the selected speed.
The backup time depends on the battery capacity and the actual load. Approximate values:
You will find a complete overview of models and specifications on the AVANSA backup power supplies page.
A leak of natural gas or propane-butane can lead to poisoning, suffocation, fire or explosion. The AVANSA 100M detector picks up gas at a concentration as low as 10% of the lower explosive limit (LEL) with a response time of under 30 seconds and triggers a visual and audible alarm of more than 90 dB. As a set with a solenoid valve (G1/2" DN15, G3/4" DN20 or G1" DN25), it also shuts off the gas supply by itself.
Carbon monoxide (CO) is colourless, odourless and non-irritating, so poisoning strikes without warning – a sleeping person may not notice it at all. A gas detector cannot recognise carbon monoxide or smoke. CO calls for the separate AVANSA 150MC detector with a sensitivity of 150 ppm ± 80 ppm and an alarm of more than 85 dB.
You can compare all models and valve sets on the AVANSA detectors page.
A few simple tasks at the right time extend the life of the pump and battery and ensure that the safety equipment works when it is needed.
Pumps, thermostats, backup power supplies, detectors and accessories with current prices and availability from our warehouse in Žilina. Installers and resellers are welcome to buy on wholesale terms via atria-europe.com. For help with your choice, call our technical line on +421 917 133 664.
Short videos showing the products, installation and settings.
User manuals, technical data sheets and declarations of conformity for the products on this page (PDF).
Our technician usually replies on the same working day.
call+421 917 133 664 · mailinfo@atria.sk
All our brands, specialist websites and online stores in one place.